Features of the diesel heater Thermo 90 ST strong>
With particularly high demands on output power, diesel heaters can operate with an output power of 9.1 kW for 2 hours from the moment of switching on. Thermo 90 S and Thermo 90 ST heaters consisting of the following components:
- air blower; li >
- heat exchanger;
- burner with flame tube;
- circulation pump.
To control the processes, the heater is equipped with: span >
- cont rol unit (external);
- flame sensor;
- incandescent pin;
- temperature sensor;
- heating limiter.
In the diesel modification, if the temperature of the coolant approaches the threshold value of the temperature of the control pause, but does not reach it, but begins to decrease within 10 minutes (after reaching the temperature of the control pause), then the heater starts to work with an output power of 9.1 kW.
As the temperature of the control pause approaches, the heater switches to an output power of 7.6 kW.
Thermo 90ST diesel heaters use fuel recommended by the manufacturer. When switching to cold-resistant (winter) fuel, the heater must be started for about 15 minutes so that the fuel has completely changed in its circuit.